Passer au contenu de la page principale

Reducing the incidence of clinically significant residual astigmatism with a low-cylinder IOL using the Barrett toric calculator

Mon statut pour la session

Quoi:
Paper Presentation | Présentation d'article
Quand:
4:58 PM, Samedi 2 Juin 2018 (3 minutes)
Authors: David B. Yan, Monica Lau
Author Disclosure Block: D.B. Yan: Employment/honoraria/consulting fees; Name of Commercial Company(s); Alcon Labratories. M. Lau: Employment/honoraria/consulting fees; Name of Commercial Company(s); Alcon Labratories.

Abstract Body:

Purpose: Determine the effect of the targeted amount of residual astigmatism on the incidence of clinically significant post-operative astigmatism when implanting a low-cylinder IOL using the Barrett toric calculator.

Study Design: Retrospective Study

Methods: A low-cylinder toric IOL (SN6AT2, ~0.68D at corneal plane) was implanted in 44 eyes of 36 patients using the Barrett toric calculator to plan residual astigmatism <0.5D, or <0.1D if the axis flips 90°. Patients were divided by amount of targeted residual astigmatism into two groups: 1) < 0.1D (n=24) and 2) 0.1D-0.5D (n=20). The residual astigmatism with a non-toric IOL was calculated using a novel vector analysis with an online tool to combine the refracted residual astigmatism with a cross-cylinder 90° from the measured axis of the toric IOL at 1-month postop.

Results: Refracted postop astigmatism with the toric IOL (0.37±0.34D) was significantly lower (p<0.001) than the astigmatism with a non-toric IOL calculated by vector analysis (0.83 ± 0.33D). Targeting <0.1D residual astigmatism on Barrett toric calculator resulted in significantly less postoperative astigmatism compared to targeting 0.1-0.5D (0.26±0.22D vs. 0.50±0.42D; p=0.02). There was also a significantly lower incidence of clinically significant postoperative astigmatism (≥0.75D) in the <0.1D targeted astigmatism group compared to the 0.1-0.5D targeted astigmatism group (4% vs. 25%, p=0.05). The refractive benefit of the toric IOL was 0.46±0.31D. Frequency analysis showed that 91% of patients had a positive refractive benefit from the toric IOL, with 80% ≥ 0.25D benefit and 61% ≥ 0.5D benefit.

Conclusions: Vector analysis is an effective tool to demonstrate the refractive benefit of a toric IOL when implanting low-cylinder toric IOLs using the Barrett Toric Calculator. Greater targeting accuracy of astigmatism management with a low-cylinder toric IOL resulted in a lower incidence of clinically significant post-operative astigmatism.

David Yan MD

Participant.e

Mon statut pour la session

Évaluer

Detail de session
Pour chaque session, permet aux participants d'écrire un court texte de feedback qui sera envoyé à l'organisateur. Ce texte n'est pas envoyé aux présentateurs.
Une fois activée, vous pouvez choisir d'afficher la liste des participants pour chaque session. Seuls les participants ayant accepté de rendre leur profil public seront affichés.
Activez cette option pour afficher la liste des participants sur la page de cette session. Ce paramètre s'applique uniquement à cette session.

Les modifications effectuées ici affecteront toutes les pages de détails des sessions sauf indication contraire