Skip to main page content

Analyzing the effective lens position and refractive outcomes of complex IOL fixation techniques

What:
Paper Presentation | Présentation d'article
When:
5:04 PM, Saturday 2 Jun 2018 (3 minutes)
How:
Authors: Yogesh Patodia, Jithin Yohannan, Ayda Shahidi, Alexander Kaplan, Iqbal Ike Ahmed
Author Disclosure Block: Y. Patodia: None. J. Yohannan: None. A. Shahidi: None. A. Kaplan: None. I. Ahmed: Grant/research support; Name of Commercial Company(s); Alcon, Abbott Medical Optics, Bausch & Lomb, Carl Zeiss. Employment/honoraria/consulting fees; Name of Commercial Company(s); Glaukos, Ivantis, Transcend, Allergan, Neomedix.

Abstract Body:

Purpose: To evaluate the effective lens position (ELP) and refractive outcomes for anterior chamber intraocular lenses (ACIOL), posterior chamber IOLs (PCIOL) in-the-bag, in the sulcus, in the sulcus with optic capture (OC), in the bag with reverse optic capture (ROC), and scleral sutured lenses (SS).

Study Design:
Single-centre, retrospective, investigational cohort study.

Methods: 213 eyes, 194 patients that underwent cataract from Jan. 2005 to Oct. 2017. 51 eyes had ACIOLs, 61 eyes with in-the-bag, 30 eyes with sulcus, 43 eyes with OC, 19 eyes with ROC, and 9 eyes with SS PCIOLs . The primary outcome was ELP (measured by anterior-segment OCT from the anterior corneal vertex to the anterior surface of the IOL) and the secondary outcome was mean arithmetic error (MArE); measured as the difference between post-operative refraction and pre-operative targeted refraction for in-the-bag placement (with the exception of the ACIOL group). ELP and MArE were reported as mean, in millimeters (mm) and diopters (D) ± standard deviation, respectively.

Results: In the following groups, ELP was determined to be: 3.41±0.45 mm in the ACIOL group, 4.44±0.31 mm for in-the-bag, 4.31±0.37 mm in sulcus, 4.54±0.41 mm in OC, 4.16±0.37 mm in ROC, and 3.92±0.67 mm in SS. The MArE of each group was determined to be: -0.38±0.69 D for ACIOL, -0.28±0.76 D for in-the-bag, -0.84±1.00 D in sulcus, -0.30±0.97 D in OC, -0.67±0.77 D in ROC, and -0.73±1.10 D in SS.

Conclusions: This study suggests that there can be variability in post-operative refractive outcomes in complex IOL fixation strategies. This variability should be taken into account pre-operatively when calculating the lens power to ensure optimized visual outcomes.
Session detail
Allows attendees to send short textual feedback to the organizer for a session. This is only sent to the organizer and not the speakers.
To respect data privacy rules, this option only displays profiles of attendees who have chosen to share their profile information publicly.

Changes here will affect all session detail pages